Test
Kits
|
Description
|
|
pH
|
pH
of water indicates the intensity of acidic / basic nature.
Low pH is corrosive to system where as high pH causes
scaling.
|
|
Total
Hardness
|
Calcium
& Magnesium can precipitate to form scaling in
boilers, cooling towers & heat exchangers.
|
|
Total
Hardness
|
Calcium
& Magnesium can precipitate to form scaling in
boilers, cooling towers & heat exchangers.
|
|
Calcium
Hardness
|
Calcium
can precipitate to form scaling in boilers, cooling towers
& heat exchangers.
|
|
Alkalinity
(P&M)
|
For
proper pH Control, to prevent scaling & corrosion in
boilers, cooling towers & heat exchangers. It is
primarily a function of carbonates, bicarbonates &
hydroxides.
|
|
Chlorides
|
Excess
level of chlorides in water may lead to corrosion in
boilers, cooling towers & heat exchangers and also
salty taste of potable water. It also indicates the cycle
of concentration in boilers.
|
|
Chlorides
|
Excess
level of chlorides in water may lead to corrosion in
boilers, cooling towers & heat exchangers and also
salty taste of potable water. It also indicates the cycle
of concentration in boilers.
|
|
Free
Chlorine
|
For
effective disinfection, a residual level of chlorine is
required.
|
|
Nitrite
|
Nitrite
is used in closed cooling systems for corrosion
protection.
|
|
Phosphate
|
Phosphates
are used to control corrosion and scaling in boilers.
Orthophosphate residual is to be maintained in water.
|
|
Sulphite
|
Sulphite
may occur in boiler feed water treated with sulphite to
control dissolved oxygen. Excess sulphite may lead to
corrosion.
|
|
Silica
|
Silica
in water is undesirable for various industrial uses as it
forms silicate scales, which are difficult to remove.
|
|
Silica
|
Silica
in water is undesirable for various industrial uses as it
forms silicate scales, which are difficult to remove.
|
|
Silica
|
Silica
in water is undesirable for various industrial uses as it
forms silicate scales, which are difficult to remove.
|
|
Iron
(Total)
|
Iron
present in source water or from corrosion of steel can
oxidize to form rust deposits with in boilers, cooling
towers and heat exchanger.
|
|
Sequestrant
or Chelant
|
Different
chemicals are used to holdup metal ions and prevent
scaling in boilers & cooling towers.
|
|
T.D.S.
Meter
|
|
|
Conductivity
Meter
|
|
|
pH
Meter
|
|
COMBINATION KITS
1. INNOVA:
Boiler Water & Cooling Water Analysis Kit : It contains
eight of the most important tests in a universally accepted
range – pH, Total Hardness, Calcium Hardness, Alkalinity,
Chloride, Free Chlorine, Nitrite, Phosphate, Sulphite, Silica,
Iron & Chelant.
2.
INNOVA:
Water Potability Test: Contains tests of Hardness, Alkalinity,
Chloride, Calcium Hardnessm pH, Nitrite, Iron and E-Coli.
3.
INNOVA:
Sugar Juice Analysis Kit: Contains tests of CaO, Sulphate,
Phosphate & Silica.
|