ICI - 721, 722, 723, 724, 726
Descaling Chemical
Your most reliable companions for
de-scaling of a wide range of process equipment such as
Boilers, Condensers, Heat Exchangers etc
A DESCALANT FOR COMPLETE DESCALING PROCESS
SHOULD INCLUDE.
- A chemical keeping in mind the
metallurgy of equipment.
- An inhibitor keeping in mind the
operating temperature and metal.
- An anti-silica compound for the
removal of troublesome silicate scale.
- A chemical to remove trouble some
calcium phosphate scale.
- A surfactant to remove oil & grease,
which interferes with effective cleaning.
- Scale softening prior to de-scaling
& neutralizing after de-scaling.
HOW TO
CHEMICALLY CLEAN YOUR HEAT EXCHANGERS
Scales, deposits and sludge of various forms can form in the heat
exchangers. Few of then may present serious problems to the equipment
- like scaling of cooling tower tubes. Accumulated deposits could be
due to any reason i.e. scaling, corrosion or suspended matters. There
are various methods of chemical cleaning is the most widely used
process adopted for De-scaling and removal of deposits.
What constitutes a Descaling Operation
Scale Softening - Prior to
descaling - An Alkaline treatment - ensures that hard rock like
deposits softens and total removal of oil contents in your boiler /
heat exchanger .
Descaling - An acidic treatment - Then quickly penetrate,
disintegrate and dissolve the scale deposits. It must be incorporated
with efficient corrosion inhibitors to ensure total protection of
metal of your costly equipments.
Neutralizing - An alkaline treatment- Must be used to dissolve
left over scale spots and neutralizing of acid traces.
Passivators - is must to prevent chances of underneath
corrosion etc.
Trained and experienced company rather than local operators should
perform these operations, unless they are fully trained to employ
proper technique and to take pre- caution against Industrial hazards.
Our Products
ICI-721
It is a powerful scale, calcium, and lime and rust remover
suitable for use on most materials.
It does not present the same health and safety concerns associated
with most other mineral acid base products.
It is effective as it will clean and remove calcium and water hardness
deposits, or rust & scale off steel within seconds and at room
temperature! Equivalent active 5% solutions of It will consume
approximately twice the amount of calcium than phosphoric acid based
products and about Four times more than conventional products
available in the market.
It is versatile as it can be used in just about any cleaning
application where acid base products are used.
It is stable for up to one year or longer when stored as recommended.
ICI-722
It is an effectively inhibited cleaner, which is formulated to
remove deposits in all types of non-potable water systems. It easily
removes deposits of calcium carbonate, calcium phosphate, and/or iron
oxides without attacking the underlying metal surfaces. The chemical
used in it converts these deposits into water-soluble salts; iron
oxide removal is hastened by the ability to form a stable soluble
complex with the iron in the deposits. The organic inhibitor system
used in it electrolytically protects metal surfaces from attack by the
de-scaling chemical.
ICI-723
It is an effectively inhibited blend with corrosion inhibitors and
wetting agents designed for cleaning typical heat transfer surfaces in
cooling towers and boiler. It easily removes deposits of calcium
carbonate, calcium phosphate, and/or iron oxides without attacking the
underlying metal surfaces. It converts these deposits into
water-soluble salts; iron oxide removal is hastened by the ability to
form a stable soluble complex with the iron in the deposits.
ICI-724
When the cleaning is complete, the chemical is forced out through
the lower drain nose. Then heat exchanger is filled with hot de-areated
water, drained filled and drained again in each instance under a
nitrogen blanket to prevent flash rusting. It is essential to keep the
inside of the heat exchanger as free from air as possible to avoid
extensive oxygen pitting. Finally an neutralizing / passivating
solution is pumped in the heat exchanger and allowed to soak for one
hour.
This treatment neutralizes residual acidity and provides a passive
surface on the cleaned metal that resists rusting when the Heat
Exchanger is opened for inspection and repairs.
ICI-726
SOFTENING: - The purpose of softening prior to de-scaling is to
soften the hard deposits, neutralize oil contents if any. Softening
compound is pumped in to the Heat Exchanger and diluted with make up
water. The final concentration depends upon quantum of scale and its
nature; normally 6000 - 15000 ppm of ICI-726 is required. The pressure
is raised and solution is circulated from, 4 - 24 hrs., during which
time the concentration of softening agent is checked from time to
time. More chemicals are added if concentration falls below 6000ppm
level. After dumping the alkaline solution and rising once or twice
with deareated fresh water the Heat exchanger is ready for descaling.
|